OVERVIEW
Specifically designed to face the rigor of winter, the Osburn 3500 with Ash Pan Pedestal with Heat Activated Variable Speed Blower is an essential for any spacious home, especially in harsh weather conditions. Despite its emissions below 2.0 g/h, this wood stove utilizes a user-friendly, non-catalytic technology as well as a significant reduction of fuel consumption. The unit features a firebox that can hold up to 50 lb of cordwood, as well as a blower, a thermodisc and an airmate for optimal heat distribution and unparalleled comfort.
A choice of door overlay, a fire screen, a glass ash lip are available as options..
Required to complete the wood stove:
Appliance Performance
Fuel type : |
Dry cordwood |
Recommended heating area-ft² : () |
1,000 - 2,700 |
Overall firebox volume : |
3.5 |
EPA loading volume-ft³ : |
2.84 |
Maximum burn time : () |
10 h |
Maximum heat output (dry cordwood) : (2) |
110,000 BTU/h (32.2 kW) |
Overall heat output rate < : (2) (3) |
18,200 BTU/h (5.3 kW) to 49,500 BTU/h (14.5 kW) |
Average overall efficiency (EPA cribs/Douglas fir) : (3) |
N.A. (HHV) (4) |
N.A. (LHV) (5) |
Average overall efficiency (dry cordwood) : (3) |
71 % (HHV) (4) |
76 % (LHV) (5) |
Optimum efficiency : (6) (7) |
77 % |
Average particulate emissions rate : (8) |
1.32 g/h |
Average CO : (9) |
92 g/h |
(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.
() Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb./ft³ and 20 lb./ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb./ft³ and 12 lb./ft³. The moisture content is between 19% and 25%.
(3) As measured per CSA B415.1-10 stack loss method.
(4) Higher Heating Value of the fuel.
(5) Lower Heating Value of the fuel.
(6) Performances based on a fuel load prescribed by the standard at 7 lb./ft³ and with a moisture content between 19% and 25%.
(7) Optimum overall efficiency at a specific burn rate (LHV).
(8) This appliance is officially tested and certified by an independent agency.
(9) Carbon monoxide.
General Features